We offer domestic oil boiler servicing, installation and repairs
within a 10 mile radius of Burtle, Somerset
Servicing
Our boiler servicing is comprehensive and thorough, as called for by OFTEC form CD11.
Internal baffles are removed, cleaned and inspected, including secondary heat exchangers if fitted. The burner nozzle will be replaced and any seals required. A combustion analysis will complete the boiler element of the service to ensure combustion gases are at the correct levels.
An external oiler boiler stripped down ready to clean.
The oil line and tank are inspected and parts cleaned/replaced as required. On the first service, a fire and environmental risk assessment of the installation as a whole is carried out.
Baffle cleaning door removed ready for cleaning.
Baffles and vortex generators cleaned, cleaning door rope seal replaced.
Installations
All notifiable works are carried out under OFTEC self-certification scheme, which means you'll receive a Building Regulations completion certificate from your Local Authority on completion of works. Workmanship is covered for 7 years under OFTEC's Workmanship Warranty scheme and Grant boiler warranties can be extended from 2 > 5 years and 5 > 10 years (model dependent), as we are Grant G1 scheme accredited installers.
Grant external boiler installed on raised plinth at property following flooding.
High level flue kit installed to prevent entrapment of flue gases under canopy.
Nuisance flue gas plume at ground level caused by incorrectly sited boiler solved by retrofit high level plume diverter kit.
Repairs
With 27 years engineering experience, accurate fault diagnosis and repair of oil boiler breakdowns is at the heart of the business and we will have you back up and running in no time. We also carry out warranty repairs for Grant UK so if your boiler develops a fault within its warranty period, just give us a call and we'll arrange authority with Grant to carry out the repair.
Oil pump stem coil showing incorrect resistance.
Failed oil pump cause traced back to ingress of water into failed oil air separator.
Incorrect flue gas reading traced back to oversized oil nozzle, also causing internal baffle damage.
Get in touch